Ventilation System Settings Table; System Test Menu - Aprilaire 8910 Safety & Installation Instructions

Touch screen thermostat with integrated indoor air quality solutions
Hide thumbs Also See for 8910:
Table of Contents

Advertisement

SETUP & TESTING

Ventilation System Settings Table

System setting
Description
Fresh Air Vent Installed
Selects if ventilation is installed . (If set to No, no other
ventilation settings will be available .)
Fresh Air Setup Type
Selects if ventilation is configured through the Code setup
or Comfort . Comfort setup has more lockout options . Code
setting ensures missed lockout time is made up .
Number of Bedrooms
Selects the number of bedrooms to be used for the Calculated
Minutes per Hour .
Home Size
Selects the size of the home to be used for the Calculated
Minutes per Hour .
Measured CFM
Selects the ventilation CFM to be used for the Calculated
Minutes per Hour .
Calculated Minutes
Displays the Fresh Air Time calculated .
per Hour
Override
Manual adjustment of Calculated Minutes per Hour .
Enable High Vent RH
Selects if ventilation is disabled if the indoor RH exceeds the
Limit
indoor RH limit . (Only available if Fresh Air Setup is set to
Comfort .)
High Vent RH Limit
Sets the ventilation indoor RH lockout limit . (Only available if
Enable High Vent RH Limit is set to Yes .)
Enable Low Vent RH
Selects if ventilation is disabled if the indoor RH exceeds the
Limit
indoor RH limit . (Only available if Fresh Air Setup is set to
Comfort .)
Low Vent RH Limit
Sets the ventilation indoor RH lockout limit . (Only available if
Enable Low Vent RH Limit is set to Yes .)
Enable High Vent
Enables high ventilation temperature lockout limit . (Only
Temperature Limit
available if Outdoor Sensor is set to Installed .)
High Vent Temperature
Sets high ventilation temperature lockout limit . (Only available
Limit
if Enable High Vent Temperature Limit is set to Yes .)
Enable Low Vent
Enables low ventilation temperature lockout limit . (Only
Temperature Limit
available if Outdoor Sensor is set to Installed .)
Low Vent Temperature
Sets low ventilation temperature lockout limit . (Only available
Limit
if Enable Low Vent Temperature Limit is set to Yes .)
HVAC Fan with Vent
Selects if ventilation forces the fan on . (Yes with high and low
limits is only available if Outdoor Sensor is set to Installed .)
Enable High Mixing
Enables high mixing temperature . (Only available is HVAC Fan
Temperature
with Vent is set to Yes with high and low limits .)
High Mixing
Sets the high mixing temperature . (Only available if Enable
Temperature
High Mixing Temperature is set to Yes .)
Enable Low Mixing
Enables low mixing temperature . (Only available is HVAC Fan
Temperature
with Vent is set to Yes with high and low limits .)
Low Mixing
Sets the Low mixing temperature . (Only available if Enable
Temperature
Low Mixing Temperature is set to Yes .)
16
Factory default setting (bold)
and setting range
No
Yes
Comfort
Code
3 Bedrooms
1 to 10 Bedrooms
2500 SQ FT
500 to 7500 SQ FT
110 CFM
30 to 250 CFM
None
Range 6 to 60 Minutes
(Calculated Minutes per Hour)
Range 6 to 60 Minutes
Yes
No
55%
45% to 70%
No
Yes
20%
10% to 30%
No
Yes
100°F (38°C)
85°F to 105°F (29°C to 41°C)
No
Yes
10°F (-12°C)
-10°F to 40°F (-24°C to 6°C)
Yes
Yes with high and low limits
No
No
Yes
80°F or (26°C)
60°F to 105°F (14°C to 41°C)
No
Yes
40°F (6°C)
0°F to 50°F (-18°C to 12°C)
SETUP & TESTING

SYSTEM TEST MENU

The system test menu is used to test a system after installation . The outputs of the thermostat can be manually
activated to test their function . The instructions below show how to enter the test mode and turn outputs on and off .
HOW TO ENTER THE SYSTEM TEST MENU:
Press [MODE] to set system to off .
Press and hold [FAN] and [MODE] for three seconds
to enter system test mode .
The first screen of the installer test displays the
equipment configuration .
Press [NEXT] to enter the first installation test or
[CANCEL] to exit .
TEMPERATURE
Each equipment test will begin with the selection of turning on the output or stage as shown below .
Press
or
to change the selection .
Press [NEXT] to accept the selection and proceed to the next step .
If YES is selected, the thermostat will test the corresponding output . If NO is selected, the thermostat will proceed
to the next step .
TEMPERATURE
EQUIPMENT TEST
SELECTION
SYSTEM TEST STEPS
Heating equipment test
Cooling equipment test
Fan equipment test
Humidification equipment test
Dehumidification equipment test
Ventilation equipment test
Air Cleaning equipment test
HUMIDITY
OUTDOOR
TEMPERATURE
EQUIPMENT
CONFIGURATION
HUMIDITY
OUTDOOR
TEMPERATURE
TEST TO BE RUN
17