speCIFICaTIons
Temperature (Shipping)
Temperature Thermostat (Operating)
Temperature Equipment Control Module (Operating)
Relative humidity
Operating voltage
Current
Outdoor, Remote, Leaving and Return temperature sensor
Room temperature measurement
Return and Leaving temperature measurement
Outdoor temperature measurement
Setpoint temperature range
Setpoint humidity range
P.O. Box 1467 • Madison, WI 53701-1467 • Phone: 800/334-6011 • Fax: 608/257-4357
61001131 4 .15
B2206504B
24
environment
-30° to 150°F (-34° to 65°C)
32° to 120°F (0° to 48°C)
32° to 158°F (0° to 70°C)
Operating: 5% to 90% R .H . (non-condensing)
electrical
24VAC (18 – 30VAC)
Maximum: 2.5A (total), 1.0A (single output)
Maximum surge current: 5A
Control
Maximum distance: 300 feet
Display range: 32° to 99°F (0° to 40°C)
Display range: -40° to 160°F (-40° to 71°C)
Display range: -40° to 130°F (-40° to 55°C)
Heat: 40° to 90°F (4° to 32°C)
Cool: 50° to 99°F (10° to 37°C)
Humidification: 10% to 50% R .H .
Dehumidification: 40% to 90% R .H .
www.aprilairepartners.com
U.S. Patent Numbers 8,146,376, 8,596,078 and other patents pending.