Omron H3CR-A Manual page 30

Hide thumbs Also See for H3CR-A:
Table of Contents

Advertisement

H3CR-G
Engineering Data
10,000
5,000
1,000
30 VDC L/R = 7 ms
500
100
250 VAC (cosf = 0.4)
Load current (A)
Nomenclature
Star operation
indicator (green)
Delta operation
indicator (orange)
Scale range display
windows
Star operation time range selector
(select one from 6, 12, 60, and 120
at full scale)
32
Reference: A maximum current of 0.15 A can be switched at 125 VDC (cosf = 1)
250 VAC/30 VDC
(cosf = 1)
Star-delta transfer time display window
and a maximum current of 0.1 A can be switched if L/R is 7 ms. In
both cases, a life of 100,000 operations can be expected.
The minimum applicable load is 10 mA at 5 VDC (failure level: P).
Time unit display
(sec is fixed)
Time setting knob (for setting
star operation time)
Star-delta transfer time selector
(select one from 0.05 s, 0.1 s,
0.25 s, and 0.5 s)
H3CR-G

Hide quick links:

Advertisement

Table of Contents
loading