Fan Maintenance - Regency Energy U31-NG10 Owners & Installation Manual

Hide thumbs Also See for Energy U31-NG10:
Table of Contents

Advertisement

FAN MAINTENANCE

If your fan requires maintenance or replacement, access to the fan is through the plate on the rear wall
of the firebox.
NOTE: the unit MUST NOT be operated with-
out the fan access panel securely in place.
To remove fan:
CAUTION:
Label all wires prior to
disconnection when servicing con-
trols. Wiring error can cause improper
and dangerous operation.
1. Turn the unit off and allow it to cool to room
temperature.
2. Unplug or disconnect power source to stove.
3. Remove the safety screen and glass front
(see detailed instructions in this manual).
4. Remove logs.
5. Remove brick panels.
6. Remove the Grate by removing the screws
on each side of the grate.
Remove the 2 screws holding the
grate in position.
7. Remove the Burner Tray by removing the
screws on each side of the tray. Push the
tray to the left and lift up.
Remove the 2 screws,
push Burner Tray to the left, and lift off.
8. Remove the 12 screws holding the Access
Panel in place.
9. Remove the Fan Air Duct by removing 4
screws, 2 per side.
Firebox (show
as transparent)
Fan Duct
Fan Cover
Plate
Firebox Rear
Fan Mounting
Stud and Grommet
10. Unplug the black wires from the fan motor (from
inside the stove).
11. Lift Fan Assembly off of the 2 pins, tip forward
and pull through firebox opening.
12. Disconnect green wire from power cord.
Replacing fan:
Reverse above steps. Hint for pushing fan down onto
pins - rub a bit of dish soap on the grommet so it
will slide more easily onto the pin. Check to make
sure the fan is seated properly on the pins, this is
very important- try to move the fan back and forth,
there should be no noise, if there is check that the
grommets haven't come loose.
When replacing the Burner Tray, slide the aeration
adjustment rod through the opening in the front of
the Valve Assembly.
Aeration Adjustment Rod
maintenance
Fan
Regency U31-10 Gas Fireplace Insert
|
29
|
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Energy u31-lp10Energy u31

Table of Contents