Heat & Glo ST-36TRB-IPI Owner's Manual page 53

Hide thumbs Also See for ST-36TRB-IPI:
Table of Contents

Advertisement

INTERMITTENT
IGNITION
PILOT IGNITOR
MODULE 3 VAC
I
S
TRANSFORMER
ORANGE
3 VAC
WHITE
GROUND TO
FIREPLACE
PLUG IN
CHASSIS
WIRES
BATTERY PACK
(TO BROWN)
WIRE ASSEMBLY
VALVE
Figure 12.1 Intellifi re Ignition Wiring Diagram with Wall Switch or Thermostat
INTERMITTENT
IGNITION
PILOT IGNITOR
MODULE 3 VAC
NOTE: 1. Ignition module, valve, pilot, and
wall switch operate on 3 volts. 110-120 VAC
I
is required at junction box unless equipped
with battery back-up.
S
TRANSFORMER
ORANGE
3 VAC
WHITE
GROUND TO
FIREPLACE
PLUG IN
CHASSIS
WIRES
BATTERY PACK
(TO BROWN)
REMOTE
PLUG IN
VALVE
Figure 12.2 Intellifi re Ignition Wiring Diagram with Remote Receiver
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. R • 12/15
53