Heat & Glo ST-36TRB-IPI Owner's Manual page 28

Hide thumbs Also See for ST-36TRB-IPI:
Table of Contents

Advertisement

1. Top Vent - Horizontal Termination - (continued)
One Elbow
Figure 7.4
Two Elbows
H
2
Figure 7.5
28
Heat & Glo • ST-36TRB-IPI, PIER-36TRB-IPI, LCOR-36TRB-IPI, RCOR-36TRB-IPI • 2128-900 Rev. R • 12/15
H
1
INSTALLED
HORIZONTALLY
V
1
H
1
V
Minimum
H
1
1
Elbow only
1-1/2 ft.
6 in.
152 mm
2-1/2 ft.
1 ft.
305 mm
3 ft.
2 ft.
610 mm
6 ft
3 ft.
914 mm
9 ft.
4 ft.
1.2 m
12 ft.
5 ft.
1.5 m
15 ft.
6 ft.
1.8 m
18 ft.
V
+ H
= 50 ft. (15.2 m) Maximum
1
1
H
= 18 ft. (5.5 m) Maximum
1
V
Minimum
H
+ H
1
1
Elbow only
6 in.
1 ft.
305 mm
2 ft.
2 ft.
610 mm
4 ft.
3 ft.
914 mm
9 ft.
4 ft
1.2 m
12 ft.
5 ft.
1.5 m
15 ft.
6 ft.
1.8 m
18 ft.
V
+ H
+ H
= 50 ft. (15.2 m) Maximum
1
1
2
H
+ H
= 18 ft. (5.5 m) Maximum
1
2
V
1
Maximum
457 mm
610 mm
914 mm
1.8 m
2.7 m
3.7 m
4.6 m
5.5 m
Maximum
2
152 mm
610 mm
1.2 m
2.7 m
3.7 m
4.6 m
5.5 m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pier-36trb-ipiLcor-36trb-ipiRcor-36trb-ipi