Mantel And Wall Projections - Heat & Glo MEZZO36 Installation Manual

Hide thumbs Also See for MEZZO36:
Table of Contents

Advertisement

B. Mantel and Wall Projections
WARNING! Risk of Fire! Comply with all minimum clear-
ances to combustibles as specifi ed. Framing closer than the
minimums listed must be constructed entirely of noncom-
bustible materials (i.e., steel studs, concrete board, etc.)
Note: For non-combustible fi replace fi nish material (marble,
stone, etc) specifi cations refer to Section 10.A.
Combustible Mantels
Note: All measurements in inches.
MAX.
6
3
1
23
20
18
MEASUREMENT FROM
TOP EDGE OPENING
Measurement from top edge opening
to bottom of appliance = 24-1/2 IN.
Figure 10.10 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - MEZZO36 and
MEZZO48
Heat & Glo • MEZZO36/ST, MEZZO48/ST MEZZO60/ST, MEZZO72/ST Installation Manual • 2300-970 Rev. T • 3/16
56
TO CEILING
31
12
9
29
26
Note: All measurements in inches.
MAX.
3
24
Measurement from top edge opening
to bottom of appliance = 24-1/2 IN.
Figure 10.11 Minimum Vertical and Maximum Horizontal
Dimensions of Combustibles - MEZZO60 and
MEZZO72
TO CEILING
9
6
31
30
27
MEASUREMENT FROM
TOP EDGE OPENING

Hide quick links: