Heat & Glo MEZZO36 Installation Manual page 29

Hide thumbs Also See for MEZZO36:
Table of Contents

Advertisement

WARNING! Risk of Fire!
DO NOT attach elbow directly to the appliance.
• The MEZZO36/MEZZO36ST, MEZZO48/MEZZO48ST and MEZZO60/MEZZO60ST require a minimum of 24 inches of
vertical venting before attaching any elbow to the appliance.
• The MEZZO72/MEZZO72ST requires a minimum of 36 inches of vertical venting before attaching any elbow to the appliance.
MEZZO36, MEZZO48, MEZZO60
MEZZO36ST, MEZZO48ST, MEZZO60ST
V
+ V
Minimum
1
2
2 ft.
610 mm
3 ft.
914 mm
4 ft.
1.2 m
5 ft.
1.5 m
V
+ H
+ V
= 63 ft. (19.2 m) Maximum
1
1
2
H
= 23 ft. (7.1 m) Maximum
Total
Figure 4.12
Heat & Glo • MEZZO36, MEZZO36ST, MEZZO48, MEZZO48ST Installation Manual • 2300-970 Rev. T • 3/16
Top Vent - Vertical Termination
Venting with 2 elbows
H Maximum
4 ft.
1.2 m
9 ft.
2.7 m
12 ft.
3.6 m
15 ft.
4.5 m
V
2
Note: Use DVP Series
components only.
H
1
MEZZO72, MEZZO72ST
V
+ V
Minimum
H Maximum
1
2
3 ft.
914 mm
4 ft.
4 ft.
1.2 m
9 ft.
5 ft.
1.5 m
12 ft.
6 ft.
1.8 m
15 ft.
V
+ H
+ V
= 63 ft. (19.2 m) Maximum
1
1
2
H
= 23 ft. (7.1 m) Maximum
Total
V
1
1.2 m
2.7 m
3.6 m
4.5 m
29