Metal Surface Housing With Post Adapter - Secura Key ENTRACOMP 26SA User & Installation Manual

With remote open input
Hide thumbs Also See for ENTRACOMP 26SA:
Table of Contents

Advertisement

2. Mount plate to wall using appropriate fasteners. Use at least
four of six holes provided.
3. Connect power and control lines to wire leads provided as
per the wiring instructions.
4. Plug connector into reader board.
5. Place ENTRACOMP
Push housing in against wall. Secure housing to mounting
bracket in door opening using two 6-32 x 3/8 screws
provided. Secure housing to bracket at bottom using one
6-32 x 1/4 security screw provided or equivalent.
6. Place housing door into door opening and rotate key 90°
clockwise.

METAL SURFACE HOUSING WITH POST ADAPTER

(See Figure 13)
1. Mount post mount adapter (optional) to post (not supplied).
Screw 1 1/2 inch pipe coupling on rear of post mount adapter
plate to post until almost tight, stopping when reader cover is
at top (12 O'clock). A small tack weld is strongly suggested
to keep the housing from rotating on post.
2. Apply 1/8 inch bead of silicone sealant around rear perimeter
surface of mounting bracket gasket.
3. Press bracket with gasket against adapter and secure with
the four 10-32 x 5/16 pan head screws provided.
®
26SA housing over mounting bracket.
Secura Key • 26