VOIDING CARDS. Cards may also be voided (cancelled) either singly
or in blocks. Follow the instructions for validating above, replacing
the "VALID" card with the "VOID" card.
SETTING THE LATCH TIMER. The output from the relay may be set to
any number of seconds from 1 to 99. To set the latch timer, place on the
®
TOUCH CARD
reader plate the sequence of program cards representing
the number of seconds the latch is to be on, then place the "SET TIMER"
®
card on the TOUCH CARD
reader plate and remove it.
Example: Set latch timer for 15 seconds.
®
Place the "1" card on the TOUCH CARD
reader plate, remove it
®
and place the "5" card on the TOUCH CARD
reader plate, remove
®
it and place the "SET TIMER" card on the TOUCH CARD
reader
plate, and remove it.
1
+
5
+
SET TIMER
Setting the latch timer to "0" produces a 0.25 second output, timed from
®
when a valid card is placed on the TOUCH CARD
reader plate.
®
inactive
ACTIVE/INACTIVE. The ENTRACOMP
26SA may be made
®
for entry by placing the "ACTIVE/INACTIVE" card on the TOUCH CARD
reader plate and then removing it. While the reader is in the inactive mode,
the LED indicator will flash red approximately once every second. The unit
may not be programmed and will not grant access to any cards while it is
in the inactive mode. To reactivate the reader, again place the "ACTIVE/
®
INACTIVE" card on the TOUCH CARD
reader plate and remove it.