Suzuki 2006 SX4 Service Manual page 987

Hide thumbs Also See for 2006 SX4:
Table of Contents

Advertisement

A/C System Symptom Diagnosis
Condition
No cool air comes out (A/
C system does not
operate)
No cool air comes out
(radiator cooling fan
motor does not operate)
No cool air comes out
(blower motor does not
operate)
Possible cause
No refrigerant
Fuse blown
A/C switch faulty
Evaporator temperature sensor faulty
A/C refrigerant pressure sensor faulty
Wiring or grounding faulty
ECM faulty
HVAC control module faulty
Magnet clutch faulty
Compressor drive belt loosened or
broken
Compressor faulty
Compressor relay faulty
BCM faulty
Fuse blown
Wiring or grounding faulty
Condenser cooling fan motor relay faulty Check condenser cooling fan motor relay
Condenser cooling fan motor faulty
ECM faulty
HVAC control module faulty
Fuse blown
Blower motor controller faulty
HVAC control module faulty
Wiring or grounding faulty
Blower motor faulty
Blower motor relay faulty
Air Conditioning System: Automatic Type 7B-47
Correction / Reference Item
Perform recovery, evacuation and charge
referring to "Operation Procedure for
Refrigerant Charge".
Check related fuses, and then check for short
circuit to ground.
Check A/C switch referring to "Inspection of
HVAC Control Module and Its Circuit".
Check evaporator temperature sensor
referring to "Evaporator Temperature Sensor
Inspection".
Check A/C refrigerant pressure sensor
referring to "A/C Refrigerant Pressure Sensor
and Its Circuit Inspection".
Repair as necessary.
Check ECM referring to "A/C System
Inspection at ECM".
Check HVAC control module referring to
"Inspection of HVAC Control Module and Its
Circuit".
Check magnet clutch referring to "Magnet
Clutch Inspection".
Adjust or replace drive belt.
Check compressor.
Check compressor relay referring to "A/C
System Relay Inspection".
Check BCM referring to "Inspection of BCM
and Its Circuits in Section 10B".
Check related fuses, and then check for short
circuit to ground.
Repair as necessary.
referring to "A/C System Relay Inspection".
Check condenser cooling fan motor referring to
"Condenser Cooling Fan Inspection".
Check ECM referring to "A/C System
Inspection at ECM".
Check HVAC control module referring to
"Inspection of HVAC Control Module and Its
Circuit".
Check related fuses, and then check for short
circuit to ground.
Check blower motor controller referring to
"Blower Motor Controller Inspection".
Check HVAC control module referring to
"Inspection of HVAC Control Module and Its
Circuit".
Repair as necessary.
Check blower motor referring to "Blower Motor
Inspection in Section 7A".
Check blower motor relay referring to "Blower
Motor Relay Inspection in Section 7A".