Confirming Module Supervision; Removing Modules; Zone Wiring - DSC PC5020 Power864 Installation Manual

Hide thumbs Also See for PC5020 Power864:
Table of Contents

Advertisement

6. Continue this procedure at each keypad until all have
been assigned to the correct slot and partition.
How to Program Function Keys
Each of the 5 function keys on each keypad may be pro-
grammed for different operation.
1. Enter Installer Programming.
2. Press [000] for Keypad Programming.
3. Enter [1] to [5] to select function key to program.
4. Enter a 2-digit number for function key option - [00] to [30].
5. Continue from step 3 until all function keys are pro-
grammed.
6. Press [#] key twice to exit Installer Programming.
For a complete list of Function Key options, see section
'Function Keys'.

2.8 Confirming Module Supervision

By default, all modules are supervised upon installation.
Supervision is enabled at all times so that the panel can
indicate a trouble if a module is removed from the system.
To check which modules are currently connected and
supervised:
1. Press [*] [8] [Installer Code] to enter Installer Program-
ming.
2. Press [903] to display all modules.
3. The LCD keypad will allow you to scroll through the
modules.
NOTE: Module supervision will not display correctly at
an LCD5500Z v2.x and lower keypad.
In LED keypads, zone lights will be turned on according
to what modules the panel has found on the system.
Refer to the following chart:
Keypad Light
Module/Device Present
[1]
Keypad 1
[2]
Keypad 2
[3]
Keypad 3
[4]
Keypad 4
[5]
Keypad 5
[6]
Keypad 6
[7]
Keypad 7
[8]
Keypad 8
[9]
Zones 9 to 16
[10]
Zones 17 to 24
[11]
Zones 25 to 32
[12]
Zones 33 to 40
[13]
Zones 41 to 48
[14]
Zones 49 to 56
[15]
PC5100
[16]
Zones 57 to 64
[17]
PC5132
[18]
PC5208
[19]
PC5204
[20]
PC5400
[21]
PC5936
[22]
LINKS2X50/Skyroute™
[23]
DLM-4L v1.0
[24]
Escort5580(TC)
[25]
Future Use
[26]
PC520X-1
[27]
PC520X-2
[28]
PC520X-3
[29]
PC520X-4
If a module is connected but does not show as being
present, it may be due to any of the following reasons:
• it is not connected to the Keybus
• there is a Keybus wiring problem
• the module is more than 1,000'/305m from the panel
• the module does not have enough power
• the PC5132 does not have any devices added

2.9 Removing Modules

If a module is no longer required on the system, the panel
must be told to stop supervising the module. To do this:
1. Remove the module from the Keybus.
2. Press [*] [8] [Installer Code] to enter Installer Program-
ming.
3. Press [902] to enable supervision. The panel will auto-
matically search for all modules on the system, will see
that the module has been removed, and will stop super-
vising it.
4. Once the search is complete (it will take about 1 minute)
enter section [903] to confirm that the correct modules
are supervised on the system.

2.10 Zone Wiring

For a complete description of the operation of all zone
types, see section 'Basic Programming PWS Sect 3'.
There are several different ways in which zones may be
wired, depending on which programming options have
been selected. The panel can be programmed to supervise
normally closed, end of line, or double end of line loops.
Refer to the following sections to study each type of indi-
vidually supervised zone wiring.
NOTE: Any zone programmed for Fire or 24-hr Super-
visory must be wired with a single end of line (EOL)
resistor regardless of the type of zone wiring supervi-
sion selected for the panel (section [013], options [1]
and [2]). See Zone Definitions [001] [004]. If you
change the zone supervision options from DEOL to
EOL or from NC to DEOL (section [013], options [1] or
[2]), power the system down completely, and then
power it back up for correct operation.
Normally Closed (NC) Loops
To enable normally closed loops, programming section
[013], option [1] must be ON.
NOTE: This option should only be selected if Normally
Closed (NC) devices/contacts are being used.
ANY Z
ANY COM
TERMINAL
TERMINAL
Normally Closed Loops. . . . . . . . . . . . . . . Section [013], Option [1]
Single End Of Line (EOL) Resistors
To enable panel detection of single end of line resistors,
programming section [013], options [1] and [2] must be
OFF.
NOTE: This option should be selected if either Nor-
mally Closed (NC) or Normally Open (NO) detection
devices or contacts are being used.
8
ANY Z
ANY COM
TERMINAL
TERMINAL