Programmable
Fan (programmable
models
only)
The
fan
output
can be
programmed
based
on period
of the
day.
When
programming
for each day and period
the fan can be set to On or AUTO.
If the
fan
button
is pressed
to change
from
On
to Auto
or vice
versa
when
programmable
fan has been
enabled,
the manual
change
will only remain
in
effect until the next program
period,
when the programmable
fan setting
will be
changed
per the scheduled
setting.
Dry Contact
On the programmable
models,
the dry contact
that can be used for control
of an
auxiliary
device.
The dry contact
may be configured
to be closed
for a specific
number
of minutes
per hour for each period
of the program
schedule.
This can
be used to operate
a ventilator,
damper,
system
blower,
or other auxiliary
device.
There are two terminals,
DI and D2.
If it is desired
to operate
a ventilator
or other device,
the DI and D2 terminals
can be connected
directly
to the equipment.
This will provide
a closed
contact
for the specified
number
of minutes
per hour. See Option
19.
If timed control of the system
blower
is required,
the dry contact
can be used for
this function.
The
G terminal
can be connected
to one
of the dry
contact
terminals
with
the other
terminal
being
connected
to Rc and/or
Rh for timed
control of the fan. Note that this is not the same as programmable
fan Option
30.
See Wiring Diagrams
for more information.
Relays
This thermostat
uses latching
relays. When the thermostat
loses power,
the relays
will remain
in their last position
until power
is restored
and all relays are reset to
their correct
position.
Out of the box, the outputs
may appear to be On when the
thermostat
is not powered.
This is normal.
Output
states should only be checked
when the thermostat
is powered.