Download Print this page

Carrier A07049 Installation Instructions Manual page 19

Performance series ac/hp

Advertisement

A07218
Fig. 13 - Cover on Equipment
Control
Module
14. Turn
on power
to equipment.
On power
up, all display
segments
will
light for 5 sec. For the next 5 sec a 2-digit
code appears
on large display
which identifies
AC/HP
Control
configuration.
Refer to Option
33.
a. AC
--
l-stage
air conditioner,
AC, with furnace
or fan coil
b. HP
--
l-stage
heat pump, HP only with fan coil
c. H
--
heating
only system,
furnace
only or fan coil with electric
heat only
d. C
--
cooling
only system,
AC with fan coil
e. H2
--
2-stage
heat pump with fan coil
f. A2
--
2-stage
air conditioner
with fan coil or furnace
18

Advertisement

loading

This manual is also suitable for:

A07048