Interface Menu; Job Timeout; Ethernet - Konica Minolta bizhub C30P Service Manual

Hide thumbs Also See for bizhub C30P:
Table of Contents

Advertisement

9. Menu
9.8

INTERFACE MENU

9.8.1

JOB TIMEOUT

Function
• Sets the time to activate JOB TIMEOUT.
Use
• To specify the amount of time before a print job times out.
Setting
• The default setting is 15 seconds.
/procedure
9.8.2

ETHERNET

NOTE
• When the ETHERNET setting is changed, the printer restarts automatically.
A. TCP/IP
(1) ENABLE
Function
• Enables TCP/IP
• To specify that the printer is connected to a TCP/IP network.
Use
YES : Enable TCP/IP. Print can be made at TCP/IP environment.
NO : Disable TCP/IP. Print cannot be made at TCP/IP environment.
Setting
• The default setting is YES.
/procedure
NOTE
• The screen displays [IP ADDRESS], [SUBNET MASK], [DEFAULT GATEWAY],
and [DHCP/BOOTP] only when [ENABLE/YES] is selected.
(2) IP ADDRESS
Function
• Sets the IP address of the printer used for the network.
Use
• To set the printer's IP address.
Setting
1. Select [IP ADDRESS] and press the Menu/Select key.
/procedure
2. Set desired IP address (first bite) with the up key /down key
key .
3. Repeat the above procedures and set the IP address up to fourth bite.
4. Press the Menu/Select key.
NOTE
• When setting the IP address manually, [DHCP/BOOTP] (IP auto acquisition
function) setting is set to [OFF] automatically.
• When IP address is not allocated from the server, the IP address is set auto-
matically within the range "169.254.0.0. to 169.254.255.255."
136
5 seconds to 300 seconds
"YES"
Field Service Ver. 2.0 May 2007
NO
and press the right