8

Electrical Information

A. General Information
WARNING! Risk of Shock or Explosion! DO NOT wire
110-120 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: This appliance must be electrically wired
and grounded in accordance with local codes or, in the
absence of local codes, with National Electric Code
ANSI/NFPA 70-latest edition or the Canadian Electric
Code CSA C22.1.
• This appliance comes with a 110-120 VAC cord
assembly. This is required for proper operation of the
appliance (IntelliFire
Touch Ignition). An outlet box may
TM
be installed in a bottom back corner of the existing solid
fuel masonry or factory built fireplace to plug in the cord
assembly, or the supplied power cord may be routed out
onto the hearth to a nearby outlet.
• A 110-120 VAC circuit for this product must be protected
with ground-fault circuit-interrupter protection, in
compliance with the applicable electrical codes, when
it is installed in locations such as in bathrooms or near
sinks.
• Low voltage and 110-120 VAC voltage cannot be shared
within the same wall box.
• In some instances, the spark ignition of the fireplace may
cause intermittent, non-damaging, interference during
the lighting sequence with a TV plugged into the same
circuit. It is recommended that the fireplace and TV use
different circuits to mitigate the interference potential.
If interference is occurring on the same circuit, the use
of surge protectors may help alleviate the interference.
NOTICE: DO NOT wire 110-120 VAC to wall switch.
RECOMMENDED
ELECTRICAL OUTLET LOCATIONS
APPLIANCE
Figure 8.1 Electrical Outlet Detail
18
Quadra-Fire • QFI30FB-IFT, QFI35FB-IFT Installation Manual • 2555-980 Rev. C • 9/18
Electrical Service and Repair
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105 ºC rated wire. Wire must have high temperature
insulation.
• Refer to Service Parts section of appliance Owner's
Manual for replacement part information.