Quadra-Fire QVI-30FB-S Owner's Manual
Quadra-Fire QVI-30FB-S Owner's Manual

Quadra-Fire QVI-30FB-S Owner's Manual

Installation and operation
Table of Contents

Advertisement

Quick Links

Model(s):
QVI-30FB-S
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• Do not store or use gasoline or other fl am-
mable vapors and liquids in the vicinity of
this or any other appliance.
• What to do if you smell gas
- Do not try to light any appliance
- Do not touch any electrical switch. Do not
use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas suppli-
er's instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
This appliance may be installed as an OEM installation in
manufactured home (USA only) or mobile home and must be
installed in accordance with the manufacturer's instructions and
the manufactured home construction and safety standard, Title
24 CFR, Part 3280 or Standard for Installation in Mobile Homes,
CAN/CSA Z240MH.
This appliance is only for use with the type(s) of gas indicated
on the rating plate.
R
CAUTION
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09
Owner's Manual
Installation and Operation
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
In the Commonwealth of Massachusetts:
• installation must be performed by a licensed plumber
or gas fi tter;
• a CO detector shall be installed in the room where the
appliance is installed.
Installation and service of this appliance should be
performed by qualifi ed personnel. Hearth & Home
Technologies suggests NFI certifi ed or factory trained
professionals, or technicians supervised by an NFI
certifi ed professional.
1

Advertisement

Table of Contents
loading

Summary of Contents for Quadra-Fire QVI-30FB-S

  • Page 1 • installation must be performed by a licensed plumber or gas fi tter; • a CO detector shall be installed in the room where the appliance is installed. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 Owner’s Manual Installation and Operation • Leave this manual with party responsible for use and operation.
  • Page 2 The information contained in this Owner’s Manual, unless noted otherwise, applies to all models and gas control systems. Your new Quadra-Fire gas appliance will give you years of durable use and trouble-free enjoyment. Welcome to the Quadra-Fire family of appliance products! We recommend that you record the following pertinent information about your appliance.
  • Page 3: Table Of Contents

    E. Contact Information ......41 = Contains updated information. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 4: Listing And Code Approvals

    • A 110-120 VAC circuit for this product must be protected with ground-fault circuit-interrupter protection, in compliance with the applicable electrical codes, when it is installed in locations such as in bathrooms or near sinks. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING...
  • Page 5: Getting Started

    • Installation and/or use of any component part not approved by Hearth & Home Technologies. Any such action may cause a fi re hazard. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Inspect appliance and components for damage.
  • Page 6: Inspect Firebox

    • Cracks that penetrate entirely through the firebrick material. Inspection for cracking should be run when the appliance is cool. Cracks tend to close as the appliance heats up. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 7: Fireplace Size Requirements

    fl oor as tested for and as noted above. NOTE: For actual appliance dimensions refer to Section 15. MINIMUM FIREPLACE SIZE Location Inches 30-1/4 14-1/8 22-1/2 Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 FRONT VIEW QVI30FB-S Millimeters 768.4 482.6 358.8 571.5...
  • Page 8: Clearances

    • Locate and install appliance to all clearance specifi cations in manual. EXHAUST VENT PIPE Figure 3.2 Clearances to Mantels or other Combustibles Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 INLET AIR 12 in. MAX. VENT PIPE MANTEL 12 in.
  • Page 9: Termination Locations

    OVERHANG VERTICAL WALL ROOF PITCH IS X/ 12 H (Min.) Ft. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Fire Risk. Asphyxiation Risk. • Terminations MUST meet minimum clearances. • Exhaust gases are hot. • Nearby vents may draw fumes into house.
  • Page 10: Vent Information And Diagrams

    PIPE - 3 FT. MIN. REQUIRED (INCLUDED) INLET AIR VENT PIPE COLLAR ATTACHMENT BRACKET Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Fire Hazard. Explosion Risk. Asphyxiation Risk. Do NOT connect this gas appliance to a chimney fl ue serving a separate solid fuel or gas burning appliance.
  • Page 11: Installation Preparation

    fi rebox of the wood- burning fi replace (see photo below). EXISTING BOTTOM OF Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Fire Risk. This fi replace has been converted for use with a gas fi...
  • Page 12: Installing Vent Pipe And Appliance

    WARNING: DO NOT BLOCK PIPE END WITH INSULATION OR ANY OTHER SEALING MATERIAL STAINLESS STEEL PIPE - 3 FT. MIN. REQUIRED (INCLUDED) INLET AIR VENT PIPE COLLAR ATTACHMENT BRACKET Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 13: Placing, Securing And Leveling The Appliance

    OR terminate within chimney. • Do NOT allow vent to sag below connection point to appliance. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Fire Risk. Only an approved Hearth & Home Technologies surround may be used to cover integral grills on solid fuel burning fi...
  • Page 14: Installing Adaptor And Termination Cap

    Note: Untwist the pipe while extending it, to achieve full 30’ length. INLET AIR VENT PIPE Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 CAUTION Sharp Edges • Wear protective gloves and safety glasses during installation. Factory Built Wood Burning...
  • Page 15: Gas Information

    • Check all fi ttings and connections of appliance which Propane may have loosened during shipping. 11.0 inches w.c. 14.0 inches w.c. 10.0 inches w.c. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Gas Leak Risk • Support control when attaching pipe to prevent bending gas line.
  • Page 16 To identify the proper orifi ce size, check with the local gas utility. If installing this appliance at an elevation above 4500 feet (in Canada), check with local authorities. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 17: Electrical Information

    • If desired an additional wall switch or thermostat may be added to system as shown in Figure 9.1. ON/OFF SWITCH Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Wire 110V to electrical junction box. Do NOT wire 110V to valve.
  • Page 18: Junction Box Installation

    • Reinstall the cover plate back on the unit. Make sure the fan does not make contact with the back wall to prevent noise from vibration. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 COVER PLATE GROUND...
  • Page 19 C RATED WIRE. Figure 9.4 Fan Wiring Diagram JUNCTION BOX GROUND 110-120 VAC BEND UP TABS (ATTACH TO ANY METAL SURFACE) Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 BLOWER RECEPTACLE BLOWER JUNCTION TEMPERATURE SENSOR SWITCH SPEED CONTROL (RHEOSTAT) GROUND WIRE...
  • Page 20: Finishing

    fi replace if necessary. Refer to surround instruc- tions provided with the decorative surround. 12 in. MIN. TOP EDGE OF UNIT Figure 10.2 Trim Surround Installation Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 LOCATING TABS FIREBOX LOCATING SLOTS...
  • Page 21: Appliance Setup

    • Save the remaining ember materials for use during appliance servicing. The embers provided should be enough for 3 to 5 applications. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 BURNER PAN SHUTTER...
  • Page 22: Positioning The Logs

    Place log #1 by locating the legs of log over the air defl ector. The notch or the Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 LOG PLACEMENT...
  • Page 23 Slide log all the way back on tab and grate. LOG #4 (SRV340-704): Place log #4 across log #1 and log #2 in the grooved out areas as shown. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 24 #5 and the left end of the log sits in the horizontal carved out section of log #1. LOG #7 (SRV740-707): Place log #7 across logs #1 and #3 in the grooved out areas as shown. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 25: Glass Assembly

    Figure 11.16 Glass Assembly G. Air Shutter Setting Optimal fl ame appearance is dependent on the air shutter setting. Adjustments should be made by a qualified technician. QVI-30FB-S Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 FIREBOX 3/8 in. Full open...
  • Page 26: Operating Instructions

    Immediately call a qualifi ed service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING HOT SURFACES! Glass and other surfaces are hot during operation AND cool down.
  • Page 27: Lighting Appliance

    Bedroom or a Bedsitting Room. For assistance or additional informa- tion, consult a qualifi ed installer, ser- vice agency or the gas supplier. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 LIGHTING INSTRUCTIONS 1. Turn off all electric power to the appliance.
  • Page 28: Check Pilot Flame Appearance

    This will help avoid setting off smoke detectors, and help eliminate any odors associated with the appliance’s initial burning. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 WARNING Glass door must be in place when appliance is operating.
  • Page 29: Frequently Asked Questions

    This noise does not affect the operation or longevity of the appliance. In a standing pilot system the pilot will always stay on. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 CAUTION • Open windows for air circulation.
  • Page 30: Troubleshooting

    With the pilot in the ON position, disconnect the thermopile leads from the valve. Take a reading at the thermopile leads. The read- ing should be 325 millivolts minimum. Replace the thermopile if the reading is below the minimum. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 Corrective Action...
  • Page 31 Ensure that the glass is tightened properly on the unit, particularly on top corners. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 Corrective Action...
  • Page 32: Maintaining And Servicing Appliance

    Refer to maintenance instructions. • Combustible materials blocking cap may ignite. • Restricted air fl ow affects burner operation. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 CAUTION Handle glass assembly with care. NOTE: Clean glass after initial 3-4 hours operation.
  • Page 33 1. Verify operation of remote. 2. Replace batteries in remote transmitters and battery-powered receivers. 3. Verify batteries have been removed from battery back-up IPI systems to prevent premature battery failure or leaking. Maintenance Tasks Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 34: Reference Materials

    QVI-30FB-S Location Inches Millimeters 6-1/2 29-3/8 26-1/16 20-5/8 15-3/16 22-1/8 21-1/4 Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 4 in. 102 mm 13-3/4 in. 350 mm ø 2-13/16 in. 1-1/16 in. 28 mm ELECTRICAL ACCESS (IF EQUIPPED) 71 mm 3-9/16 in.
  • Page 35: Vent Kits Components

    FLEX3-30/2: Two 3 inch fl exible liners expands to 30 feet each. FLEX-CNCT: Connector kit - 3 inch liner to 3 inch liner, one connector per kit. Figure 15.3 Direct Vent Flex Liner Accessory Kits Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 FLASH-DAMP LINK-ZC-ADP SVRLINK-ADP FLEX3-30...
  • Page 36: Service Parts

    QVI-30FB-S C. Service Parts Service Parts Diagram Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date:_____ Log Set Assembly Part number list on following page. Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 37 Pilot Orifi ce NG Pilot Orifi ce LP Regulator NG Regulator LP Additional service part numbers appear on following page. COMMENTS Qty 2 Req Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 QVI-30FB-S Stocked at Depot PART NUMBER LOGS-QVI30FB SRV2020-140...
  • Page 38 Flex Ball Valve Assembly Valve NG Valve LP Flame Control Knob Pilot Control Knob Bracket: Valve COMMENTS Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09 QVI-30FB-S Beginning Manufacturing Date: Oct. 2007 Ending Manufacturing Date:______ PART NUMBER 2103-010 2103-011 768-432...
  • Page 39: Limited Lifetime Warranty

    D. Limited Lifetime Warranty Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 40 D. Limited Lifetime Warranty (continued) Quadra-Fire • QVI-30FB-S • 2020-910 Rev. H • 6/09...
  • Page 41: Contact Information

    E. Contact Information Please contact your Quadra-Fire dealer with any questions or concerns. ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ ________________________________________________________________________________ • Important operating a n d m a i n t e n a n c e instructions included.

Table of Contents