Needle Plate Base Assembly Attachment - Brother PR600II Service Manual

Hide thumbs Also See for PR600II:
Table of Contents

Advertisement

Main unit
6

Needle plate base assembly attachment

1. Attach the needle plate base assembly 1 to the arm bed with the 2 screws
1.
*Key point
• Attach the needle plate base assembly 1 so that it is parallel
to the arm bed.
2. Attach the cutter link assembly's shaft 2 while aligning it with the hole on
the movable knife.
3. Connect the cutter unit's lever link assembly 3 to the cutter link assembly
with the 2 screws 2.
*Key point
• Temporarily tighten the screws 2 first. Firmly tighten them
after completing 4 - 33 "Movable knife origin adjustment."
Start movie clip (CD-ROM version only)
1
2
7
Needle plate attachment
1. Attach the needle plate to the needle plate base assembly with the 2 screws 1.
1
3 - 94
Main unit
Screw, Pan
M4X8
Screw, Bind
M3X4
Screw
M4
Torque
1.18 – 1.57 N-m
Torque
Hand start
Torque
0.78 – 1.18 N-m
1
1
2
2
3
1