Main unit
12

FFC and X-area sensor assembly attachment

1. Bend the free end of the FFC (SML2CD-X) connected to the hoop PCB
assembly 90 degrees at two points, connect it to the X-area sensor
assembly 1, and lock the connector.
2. Connect the FFC (SML2CD-C) 2 to the X-area sensor assembly, and lock
the connector.
3. Attach the X-area sensor assembly and the X-frame spacer 3 to the feed
frame assembly with the screw 1.
4. Hold the FFC (SML2CD-X) with sheet B 4, and secure the FFC to the
feed frame assembly with the 2 screws 2.
5. Thread the FFC (SML2CD-C) through the slot 5 on the feed frame
assembly.
6. Hold the FFC (SML2CD-C) with sheet C 6, and secure the FFC to the
feed frame assembly with the screw 3.
Start movie clip (CD-ROM version only)
1
2
3
3 - 84
Feed unit
Screw, Pan (S/P washer)
M3X10
Screw, Bind
M3X4
6
5
Torque
0.59 – 0.78 N-m
Torque
0.59 – 0.78 N-m
3
4
2
1
2
3
2
1