15. ELECTRICAL EQUIPMENT
Starter Motor Removal/Disassembly
Remove body cover.
Remove bolt and oil pump control cable.
Disconnect starter motor harness coupler.
Remove 2 bolts for separation starter motor and
Starter motor
gasket.
Remove 2 bolts for disassembly the starter motor.
Coupler
Armature
Motor housing
Spring
O-ring
Carbon bracket
Front bracket
Armature Inspection
Check the armature for discoloration or other
damage. It may be short-circuit if dark surface on
the shifter found.
Caution
Do not clean the shifter surface with sandpaper.
Check continuity 1) both the shifter surface and
shaft, 2) among the shifter surfaces. It can be in
continuity among the shifter surfaces, but both the
shifter surface and the shaft can not be in
continuity.
Starter Motor Re-Assembly/Installation
Re-assemble and install the starter motor in
reverse order of removal procedures.