Viewing The Test Log; Diagnostic Error Message Tables - IBM Netfinity 7100 User's Reference Manual

Hide thumbs Also See for Netfinity 7100:
Table of Contents

Advertisement

2. When the message F2 for Diagnostics appears, press F2.
3. Type in the appropriate password; then, press Enter.
4. Select either Extended or Basic from the top of the screen.
5. When the Diagnostic Programs screen appears, select the test you want to run
When the tests have completed, you can view the Test Log by selecting Utility from
the top of the screen.
If the hardware checks out OK but the problem persists during normal server opera-
tions, a software error might be the cause. If you suspect a software problem, refer to
the information that comes with the software package.

Viewing the test log

The test log will not contain any information until after the diagnostic program has run.
Note: If you already are running the diagnostic programs, begin with step 3
To view the test log:
1. Turn on the server and watch the screen.
2. When the message F2 for Diagnostics appears, press F2.
3. When the Diagnostic Programs screen appears, select Utility from the top of the
4. Select View Test Log from the list that appears; then, follow the instructions on

Diagnostic error message tables

The following tables provide descriptions of the error messages that might appear
when you run the diagnostic programs.
124
IBM® Netfinity® 7100 User's Reference
from the list that appears; then, follow the instructions on the screen.
Notes:
a. If the server stops during testing and you cannot continue, restart the server
and try running the diagnostic programs again. If the problem persists, call for
service.
b. The keyboard and mouse (pointing device) tests assume that a keyboard and
mouse are attached to the server.
c. If you run the diagnostic programs with no mouse attached to your server, you
will not be able to navigate between test categories using the Next Cat and
Prev Cat buttons. All other functions provided by mouse-selectable buttons
are also available using the function keys.
d. The regular mouse test cannot test a USB mouse.
e. You can view server configuration information (such as system configuration,
memory contents, interrupt request (IRQ) use, direct memory access (DMA)
use, device drivers, and so on) by selecting Hardware Info from the top of
the screen.
If the server is on, shut down your operating system and restart the server.
If a power-on password or administrator password is set, the server prompts you
for it. Type in the appropriate password; then, press Enter.
screen.
the screen.
The system maintains the test-log data while the server is powered on. When you
turn off the power to the server, the test log is cleared.