Removing the select arm (R) / link plate
Prior to performing the following procedure, remove
the top plate assembly.
1.
Bring up the select arm (R) to release from the link
plate (joint y) and turn as shown in the figure to
release the two joints z and joint a'.
2.
Move the link plate in the direction of the arrow to
release the joint b'. Remove the link plate spring at
the same time.
REFERENCE:
Before removing the link plate, remove
the select arm (L).
Reattaching the Select arm (R) / link
plate (See Fig.25 and 26)
REFERENCE:
Reverse the above removing procedure.
1.
Reattach the link plate spring.
2.
Reattach the link plate to the link plate spring while
joining them at joint b'.
3.
Reattach the joint y of the select arm (R) to the first
peak of the link plate while joining the two joints z
with the slots. Then turn the select arm (R) as shown
in the figure. The top plate is joined to the joint a'.
CAUTION:
When reattaching the select arm (R),
check if the part c' is correctly fitted and
if each part operates properly.
1-14
(See Fig.21 and 22)
Joint a'
Link plate
Joint z
Select arm (R)
Joint z
Joint s
Joint y
Link plate spring
Select lock arm
Top plate
Joint b'
Link plate
Link plate spring
Select arm (R) Joint a'
Joint z
Joint z Joint y
Joint y
Select arm (L)
Select lock arm
Fig.21
Top plate
Select lock arm
Hook u
Select lock
arm spring
Fig.22
Select arm (L)
Joint b'
Select
lock arm
Fig.25
Link plate
Fig.26