(3) Detaching and refitting the fixing heater

Follow the procedure below to replace the fixing heater.
Procedure
1. Remove the fixing unit (see page 1-6-34).
2. Remove the screw holding the fixing unit front
cover and then the cover.
3. Remove the two screws and detach the fixing
heater wire from the fixing thrmostat.
4. Remove the screw holding the fixing heater
front retainer and then the retainer.
Figure 1-6-57
Fixing heater wire
Figure 1-6-58
Figure 1-6-59
2BT
Fixing unit front cover
Fixing heater wire
Nuts
Fixing heater front retainer
1-6-35