Documentation required

The following documentation is needed for repair procedures:
Instruction booklet for specific model
Technical documentation for specific model (diagrams, exploded drawings)
1.2
Tools and resources
As well as the standard equipment, the following is required:
Qty.
Description
1
Screwdriver
1
Pliers for Oetiker clamps
1
CC -A - Vdc tester
1
Digital thermometer
1
SSC (Saeco Service Center)

1.3 Material

Description
Thermal paste
Descaler
Grease solvent
Silicone grease

1.4 Safety warnings

We recommend you consult the technical manual of the machine before performing any mainte-
nance work.
Observe all applicable standards relating to the repair of electrical appliances.
Always disconnect the power plug from the mains before beginning repair work.
Simply turning off the main machine power switch is not an adequate safety
This appliance is rated as protection class I.
Insulation and dielectric rigidity tests must be performed on completion of any repair.
Saeco International Group
Notes
Torx T 10
Scale limit > 150°C
Programmer
Notes
Heating element > 200°C
Saeco Entkalker
Personal preference
Safe to use with food
Rev.01 February 2010
01 INTRODUCTION
precaution.