Code
C4000
Polygon motor synchronization
problem
• The polygon motor does not reach
the stable speed within 15 s of the
START signal turning on.
C4010
Polygon motor steady-state problem
• The polygon motor rotation is not
stable for 5 s after the polygon motor
rotation has been stabilized.
C6000
Broken fusing heater wire
• In fusing warm-up, the time to reach
50 °C/122 °F exceeds 13.5 s, the
time to reach 100 °C/212 °F exceeds
10 s, the time to reach the primary
stabilization exceeds 10 s or the time
to reach the secondary stabilization
exceeds 24 s.
C6020
Abnormally high fusing unit ther-
mistor temperature
• The fusing temperature exceeds 230
°C/446 °F for 40 ms.
Y104230-6
Contents
Causes
Check procedures/corrective measures
Poor contact in
Reinsert the connector. Also check for con-
the polygon motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective polygon
Replace the LSU.
motor.
Defective engine
Replace the engine PWB and check for
PWB (KP-5238).
correct operation.
Poor contact in
Reinsert the connector. Also check for con-
the polygon motor
tinuity within the connector cable. If none,
connector termi-
remedy or replace the cable.
nals.
Defective polygon
Replace the LSU.
motor.
Defective engine
Replace the engine PWB and check for
PWB (KP-5238).
correct operation.
Poor contact in
Check the connection of connector YC4 on
the thermistor
the power supply PWB and the continuity
connector termi-
across the connector terminals. Repair or
nals.
replace if necessary.
Thermistor in-
Check and reinstall if necessary.
stalled incorrectly.
Thermal cutout
Check for continuity. If none, replace the
triggered.
thermal cutout.
Heater lamp in-
Check and reinstall if necessary.
stalled incorrectly.
Broken heater
Check for continuity. If none, replace the
lamp wire.
heater lamp.
Measure the resistance. If it is 0 Ω, replace
Shorted ther-
mistor.
the thermistor.
Broken heater
Replace the power supply PWB and check
control circuit on
for correct operation.
the power supply
PWB.