Olivetti d-Copia 18MF Service Manual page 58

Hide thumbs Also See for d-Copia 18MF:
Table of Contents

Advertisement

Maintenance
item No.
U901
Checking/clearing print counts by paper feed locations
Description
Displays or clears print counts by paper feed locations.
Purpose
To check the time to replace consumable parts. Also to clear the counts after replacing the consumable parts.
Method
1. Press the enter key. The print count will be displayed for each paper feed location.
Display
Bypass
Cassette 1
Cassette 2
All Clear
2. Select the paper feed location to clear the count using the up/down cursor keys. To clear all counts, select
All Clear.
3. Press the enter key. The count is cleared.
Completion
Press the back key. The indication for selecting a maintenance item No. appears.
U905
Checking/clearing counts by the DP
Description
Displays the counts of the DP.
Purpose
To check the use of the optional DP.
Method
Press the enter key. The count will be displayed.
To clear the count, press the enter key.
Completion
Press the back key. The indication for selecting a maintenance item No. appears.
U911
Checking/clearing print counts by paper size
Description
Displays or clears the paper feed count value by paper size.
Purpose
To check the time to replace consumable parts. Also to clear the counts after replacing the consumable parts.
Method
1. Press the enter key. The paper feed counts by paper size will be displayed.
2. Select the paper size to clear the count using the up/down cursor keys. To clear all counts, select All Clear.
3. Press the enter key. The count is cleared.
Completion
Press the back key. The indication for selecting a maintenance item No. appears.
1-4-16
Description
Paper source
MP tray
Cassette
Optional cassette
Clearing all counts
Service Manual
Y104230-6

Hide quick links: