Functional Test Settings - Mitsubishi Electric MR-J3-T Quick Start Manual

Servo amplifier with point table positioning
Hide thumbs Also See for MR-J3-T:
Table of Contents

Advertisement

First Functional Test
3.2

Functional Test Settings

The following input signals are required to activate the servo amplifier's motor output:
b EMG -> Force stop (safety signal)
b SON -> Servo ON
b LSP -> Forward rotation stroke end (limit switch)
b LSN -> Reverse rotation stroke end (limit switch)
You can configure the servo amplifier to activate these signals automatically when the power is
switched on:
Procedure:
Connect the PC / notebook to the servo amplifier's USB port (CN5) with the
MR-J3USBCBL3M cable.
Start MR Configurator on the computer and make the following settings:
– Select the MR-J3-T series servo amplifier:
Fig. 3-3:
MR-J3-T
Selecting the servo amplifier
Functional Test Settings
3 - 7

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents