How To Write Data By Controlling (Off To On) The Write Command - Mitsubishi Electric 700 Series Programming Manual

700 series plc function programming manual
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

1.7.3
How to write data by controlling (OFF to ON) the write
command
You can write the operation mode and set frequency to the inverter, batch-clear the
alarm definitions, and clear all parameters.
Device
No.
D9143
Operation mode setting write
D9144
Set frequency write (RAM)
Set frequency write
D9145
2
(E
PROM)
D9146
Alarm definition batch clear
D9147
All parameter clear
The above data are written as soon as the write completion turns on after the write
command has turned from off to on.
(Alarm definition batch clear (D9146) and all parameter clear (D9147) turn on at
completion of clear.)
To write the data again, the write command must be turned off once, then on again.
Data write timing chart
1) In user sequence, user
data is stored into write
data area (D914n).
Y2n(n=3 to 7)
Write command
X2n(n=3 to 7)
Write completion
D914n(n=3 to 7)
Write data
User data
3) Turns on when inverter CPU completes data
write to inverter.
Alarm definition clear and parameter
clear turn on at completion of clear.
0 written to D9150 indicates normal completion.
Any value other than 0 indicates abnormal completion.
Name
Command
2) In user sequence, write
command is turned on.
Inverter Status Monitoring, Special Registers
Write
Write
Completion
Y23
X23
Y24
X24
Y25
X25
Y26
X26
Y27
X27
4) After confirmation of write
completion, write command
is turned off.
5) Inverter CPU confirms that
write command is off and
turns off write completion.
for Control
Data Access
Enable Condition
Pr.79 =0, 2
PU operation mode
(PU LED on) or CC-
Link operation mode
(PU and EXT LEDs
flicker slowly)
Always
As set in Pr. 77
25