Mitsubishi Electric 700 Series Programming Manual page 21

700 series plc function programming manual
Hide thumbs Also See for 700 Series:
Table of Contents

Advertisement

Device Map
Number
Name
Inverter operation
D9148
status control
Inverter operation
status control
D9149
enable/disable
setting
Inverter
D9150
parameter
access error
D9151
Inverter status
Frequency
D9152
setting
D9153
Running speed
D9154
Motor torque
Converter output
D9155
voltage
Regenerative
D9156
brake duty
Electronic thermal
D9157
relay function load
factor
Output current
D9158
peak value
16
Turn on/off the corresponding bits to control the
inverter operation status.
The initial value: All "0". When M9255 is off, this
device does not function.
B15
B12B11
Invalid
Enable/disable the inverter operation status control
using D9148 and M9200 to M9211 by turning on/off
the corresponding bits.
Bit image is the same as D9148.
The initial value: All "0" (invalid)
Stores the error No. when an error occurs because
the data stored in the parameter or special register is
not reflected on the inverter.
Stores the running status and operating status of the
inverter.
B15
B8B7
0.01Hz units
1(0.1)r/min unit
0.1% units
0.1V units
0.1% units
0.1% units
0.01A/0.1A units
Description
B8B7
B4B3
B0
B4B3
B0
0:OFF
1:ON
Inverter running(RUN)
Forward running
Reverse running
Up to frequency(SU)
Overload alarm(OL)
Instantaneous power failure
/undervoltage(IPF)
Output frequency
detection(FU)
Alarm output(ALM)
Minor fault output(LF)
Page
0:OFF
1:ON
STF
31
STR
RH
RM
RL
JOG
RT
AU
CS
MRS
STOP
RES
32
33
33