7.3

Torque command by CC-Link communication

Digital torque command can be given during torque control under Real sensorless vector control and vector control using the
FR-A8NC. The torque command setting method can be selected using Pr.804 Torque command source selection.
Pr.
Name
Torque command
804
source selection

Can also be set from operation panel or parameter unit.
Initial
Setting
value
range
0
Torque command by terminal1 analog input
Torque command by CC-Link communication (FR-A8NC)
1
• Torque command by parameter setting
Setting value of Pr.805 or Pr.806 (-400% to 400%)
Torque command by CC-Link communication (FR-A8NC)
• Torque command by parameter setting
3
Setting value of Pr.805 or Pr.806 (-400% to 400%)
• Setting is available using the remote register RWw1 or RWwC.
(-400% to 400%)
0
4
16 bit digital input (FR-A8AX)
Torque command by CC-Link communication (FR-A8NC)
• Torque command by parameter setting
5
Setting value of Pr.805 or Pr.806 (-327.68% to 327.67%)
• Setting is available using the remote register RWw1 or RWwC.
(-327.68% to 327.67%)
Torque command by CC-Link communication (FR-A8NC)
6
• Torque command by parameter setting
Setting value of Pr.805 or Pr.806 (-327.68% to 327.67%)
Torque command


DETAILS OF INPUT AND OUTPUT SIGNALS
Parameter for
speed limit
Pr.807
Pr.808, Pr.809
Pr.807
Pr.808, Pr.809

Pr.807

71