Vent Configuration: Horizontal Termination (No Vertical Rise) - Travis Industries 864 HO NB GSR2 Installation Manual

Built-in direct vent fireplace
Hide thumbs Also See for 864 HO NB GSR2:
Table of Contents

Advertisement

Vent Configuration: Horizontal Termination (no vertical rise)

NOTE: A Wall thimble (part #58DVA-WT) is required.
The termination must fall within the shaded area shown in the chart. Use the indicated restrictor
positions.
NOTE: When venting horizontally, use minimum vent kit "C"
installation, an additional 45° elbow is required.
Vent with No 45˚ Elbow
3 feet (0.915m)
Vent with 1 45˚ Elbow
3 feet (0.915m)
© Travis Industries
Installation
Optional 45 Elbow
45 Elbow
0 feet
0 feet
(for qualified installers only)
(96200316). If venting from a corner
Termination
Exhaust Restrictor # 1 (stock)
Intake Restrictor # 1 (stock)
Min. 6" (152mm) Horizontal Section
Max.48" (1219mm) Horizontal Section(s)
Exhaust Restrictor # 1 (stock)
Intake Restrictor # 1 (stock)
Min. 6" (152mm) Horizontal Section
Max. 24" (610mm) Horizontal Section(s)
4140922
21
100-01410

Advertisement

Table of Contents
loading

Table of Contents