Electrical Specifications

Power Supply
Name
Phase
Frequency
Voltage
Voltage Range Minimum
Maximum
(2)
Current
Z-max
(3)
Minimum Ssc
value
Maximum
Heating
running
Current
Recommended fuses
Wiring
For power
Quantity
Connections
supply
Wire type
For connection
Quantity
with indoor
Remark
unit
Power Supply Intake
Notes
(1): European/International Technical Standard setting the limits for harmonic currents produced by equipment connected to public low-
voltage systems with input current > 16A and ≤ 75A per phase
(2): In accordance with EN/IEC 61000-3-11
equipment is connected only to a supply with Zsys
(3): Short-circuit power
(4): Select diameter and type according to national and local regulations
(5): European/International Technical Standard setting the limits for voltage changes, voltage fluctuations and flicker in public low-voltage
supply systems for equipment with rated current ≤ 75A
(6): System impedance
Specifications
ER(S/R)Q011AA(V1/Y1)
Daphne FVC68D
l
mm
mm
mm
m
m
m
m
kg/m
see installation manual
m
Both liquid and gas pipes
Reversed cycle
Sensor for outdoor heat
exchanger temperature
Inverter controlled
Fan motor thermal protector
Inverter overload protector
PC board fuse
Installation manual
bar
ER(S/R)Q(011/014/016)AAV1
Hz
V
V
V
kVa
Equipment complying with EN/
IEC 61000-3-12
A
A
(5)
, it may be necessary to consult the distribution network operator to ensure that the
(6)
≤ Zmax
ER(S/R)Q014AA(V1/Y1)
Daphne FVC68D
1,5
1
Flare
Flare
9,52
1
Flare
Flare
15,9
3
26 x 3
26 x 3
3
50
63
10
see installation manual
30
Both liquid and gas pipes
Reversed cycle
Sensor for outdoor heat
exchanger temperature
Inverter controlled
HPS
HPS
Fan motor thermal protector
Inverter overload protector
PC board fuse
Installation manual
1
40
ER(S/R)Q(011/014/016)AAY1
1~
50
220-240
380-415
198
254
0,28
(1)
27
32
2G
(4)
Note
Note
2
F1+F2
Both indoor and outdoor unit
Specifications
ER(S/R)Q016AA(V1/Y1)
Daphne FVC68D
1,5
1,5
1
1
Flare
9,52
9,52
1
1
Flare
15,9
15,9
3
3
26 x 3
3
3
50
50
63
63
10
10
see installation manual
30
30
Both liquid and gas pipes
Reversed cycle
Sensor for outdoor heat
exchanger temperature
Inverter controlled
HPS
Fan motor thermal protector
Inverter overload protector
PC board fuse
Installation manual
1
1
40
40
3~
50
342
440
-
-
13,5
16
4G
(4)
7