c. Calibrate Manually
Intended for advanced users, the calibrate manually section allows the user to manually adjust the top-
of-form sensor for specialized media. The TOF ADC Reading field displays the current top-of-form sensor
reading for the currently selected paper type and sensor side.
The values for gain, paper threshold and gap/mark threshold are shown for the currently selected paper
type and sensor side as well. These values are typically set when auto calibration is performed using the
Calibrate Paper utility.
The capture feature allows the user to lift the printhead, and using the LED as a guide place the
paper under the sensor and capture the value. Then, moving the gap (media backing) or mark under
the sensor, the value can be captured.
Note:
Performing Calibrate Paper will overwrite the threshold values.
Select Calibrate Manually to change the following settings:
Top-of-Form Gain
Paper Threshold
Gap/Mark Threshold
Adjustment Settings
TOF Gain
Paper Threshold
Gap/Mark Threshold
d. Calibrate Display
Select Calibrate Display and then select either the green Accept button to continue or the red Reject
button. Upon selecting to continue, follow the on-screen directions to properly calibrate the
touchscreen display.
If the touchscreen display becomes unusable, the printer can be calibrated during power- up as well. To
calibrate during power-up, perform the following procedure beginning with the printer powered off.
1. Press and hold the Reset button on the back of the printer.
2. Toggle the power switch to power-on the printer.
3. Continue to hold the Reset button for ten (10) seconds.
4. Follow the on-screen instructions to calibrate the display.
Note:
Allow a few minutes for power-up to complete.
Ranges
1 to 31
0 to 255
0 to 255
52