Technical Data; Dimensional Drawing - Fisher & Paykel DE6060P1 Service Manual

Hide thumbs Also See for DE6060P1:
Table of Contents

Advertisement

Service Manual
Model No: DE6060P1/DE6060G1/DE5060G1
19 Do not install or store this dryer where it will be exposed to water and /or the weather.
Keep surrounding areas free from the accumulation of lint, dust and dirt.
20 To prevent shock hazard and assure stability during operation, the dryer must be installed and
electrically grounded by a qualified service person in accordance with local codes.
21 Do not sit on top of the dryer.
22 If the supply cord is damaged, it must be replaced by the manufacturer, its service agent
or similarly qualified persons in order to avoid a hazard.
23 Always disconnect dryer from electrical supply before attempting any service.
Disconnect power cord by grasping the plug, not the cord. Do not repair or replace any
24
part of the dryer or attempt any servicing unless specifically recommended in the
user-maintenance instructions.
25 Before the dryer is removed from service or discarded, remove the dryer door to
prevent accidental entrapment.
26 Remove all objects from pockets such as lighters and matches.
Caution, risk of fire - this is a safety symbol. Failure to follow the warnings
outlined in these user instructions can cause a fire hazard.

2.Technical data

Heater:
Nominal voltage............................................240V
Total power...................................................1200W+550W
Resistance 20
leakage current............................................
NTC sensor:
Resistance NTC
0
(30.3-35.1) KΩ
10
(18.7-21.2) KΩ
25
(9.5-10.5)
35
(6.15-6.9)
50
(3.35-3.86) KΩ
70
(1.6-1.9)
80
(1.15-1.37) KΩ
leakage current..............................................
Thermostat 2 states short circuit or open circuit)............AC250V, 16(7)A, 110-20
Thermal cut-off 2 states(short circuit or open circuit).......AC250V, 16(7)A, 110
Motor:
Resistance 20
Between red wire and orange wire....................62.5Ω
Between red wire and blue wire.....................35.8Ω
Between orange wire and blue wire..................26.8Ω

3.Dimensional drawing

Dimensions
a=830 mm
b=600 mm
c=570 mm
W eight=32 kg
.........................................28.5±5%Ω
2
Issue
Rev.

Advertisement

Table of Contents
loading

This manual is also suitable for:

De5060g1De6060g1

Table of Contents