Fujitsu Eternus DX60 S2 User Manual page 99

Hide thumbs Also See for Eternus DX60 S2:
Table of Contents

Advertisement

Appendix A Event Notification Message List
A.2 Message List
Event type
and event
P DASSdd00
P DASSdd00
P DBSSdd00
When the event type is "M"
The following messages are sent when an event that requires maintenance occurs:
Event type
and event
M 21810xxx
M E005nxxx
M E10300xx
M E2070001
M E2070002
M E2070004
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
SNMP Trap
Trap
TrapItemID
Sensor
code
No.
6
DA00dd00 2
2
DA00dd00 -
2
DB00dd00 -
SNMP Trap
Trap
Trap
Maintenance
code
No.
Info
7
21810xxx
RAID Group#0xxx recovered end of Rebuild processing
Rebuilding to a hot spare or a replaced disk is complete,
but Bad Data (data lost identifier) exists.
7
E005xxxx
WRITE BAD DATA
Writing of Bad Data (data lost identifier) occurs.
7
E10300xx
PINNED DATA was created CM#m
Pinned Data occurs.
7
E2070001
NOT READY(01:Configuration Error)
The device is in Not Ready status.
Shipment settings (model setting) and configurations are
not applied.
7
E2070002
NOT READY(02:CM F/W Version Error)
The device is in Not Ready status.
Firmware version for the CM is not correct.
7
E2070004
NOT READY(04:Restore Fail)
The device is in Not Ready status.
Backup is successfully complete, but cannot perform the
restoration.
Copyright 2011 FUJITSU LIMITED
Upper: Message
Trap
Lower: Description
Info
DE Exhaust temperature DE#dd Fatal
CE exhaust temperature error or DE exhaust
temperature error (fatal error) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
DE Exhaust temperature sensor DE#dd Fault
CE exhaust temperature error or DE exhaust
temperature error (sensor failure) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
DE Intake temperature sensor DE#dd Fault
CE intake temperature error or DE intake
temperature error (sensor failure) is detected.
SS: Component subtype
dd: DE-ID ("00" for a controller enclosure)
Upper: Message
Lower: Description
xxx: RAID group number
xxx: RAID group number
xx: CM module ID in which Pinned Data occurred
m: CM number in which Pinned Data occurred
99
Remarks
These messages
are notified when
"Module was
broken" is enabled
for Error Severity
Level in the event
notification setting.
They are not notified
during maintenance
operations.
Remarks
These messages
are notified when
"RAID Degradation
Event" is enabled
for Warning Level in
the event
notification setting.
They are not notified
during maintenance
operations.
These messages
are notified when
the relevant event
occurs.
P3AM-5512-02ENZ0

Advertisement

Table of Contents
loading

Table of Contents