Fujitsu Eternus DX60 S2 User Manual page 19

Hide thumbs Also See for Eternus DX60 S2:
Table of Contents

Advertisement

Chapter 1 Components
1.1 Controller Enclosure
LEDs
The states of LEDs are listed below.
Table 1.5
SCU STATUS
IDENTIFY
DI (OUT) LINKUP
UNIT READY/
FAULT
MASTER
ACT
LINK
FAULT
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
Status and meanings of each LED (iSCSI model controller)
LED name
LED status
(green)
(blinks green)
(blinks blue)
(off)
(green)
(green)
(orange)
(green)
(green)
(green)
(orange)
Copyright 2011 FUJITSU LIMITED
The SCU is in normal status.
SCU is charging.
As ordered via ETERNUS Web GUI, the installation
location of the controller enclosure is identified.
The link between the DI (OUT) port and the destination
has been established.
The controller is in normal status.
The controller is performing the initial setup after the
power is turned on.
The controller is in error status.
The controller is set as a Master CM.
The controller is sending or receiving data via the LAN
port (for operation management).
The link between the LAN port (for operation
management) and the destination has been
established.
The link between the iSCSI port (host interface port)
and the destination has been established.
The controller is performing the initial setup after the
power is turned on.
The iSCSI port (host interface port) is in error status.
19
Controller status
P3AM-5512-02ENZ0

Advertisement

Table of Contents
loading