Chapter 7 Troubleshooting
7.1 Check List
3
4
5
When I/O access is slow
Check the following points: When the cause is not identified, contact your maintenance engineer.
Check that the ambient temperature does not exceed the operating environment conditions.
If so, Nearline SAS disk performance may be reduced.
Click the icon of each part in the Storage System Status screen of ETERNUS Web GUI to
check if an abnormality is detected in ETERNUS DX Disk storage system parts.
If an abnormality is detected, contact your maintenance engineer.
Check the controller status.
When the controller fails, the data in cache memory is directly written to the disks. This
causes temporary performance degradation.
When the controller fails, contact your maintenance engineer.
ETERNUS DX60 S2 Disk storage system User's Guide -Operation-
Re-attach the flange cover from the 2.5" type controller enclosure.
Re-attach the front cover to the 3.5" type controller enclosure.
For details on how to attach the flange cover, refer to
Flange Cover" (page
34).
For details on how to attach the front cover, refer to
Cover" (page
36).
Access ETERNUS Web GUI or ETERNUS CLI by using the default IP address
to perform the network environment settings.
Make sure that all of the desired network services are set to
IMPORTANT
"Enable".
If ETERNUS Web GUI is to be used, set "http" and/or "https" to
"Enable". If "Disable" is set, ETERNUS Web GUI access to the
ETERNUS DX Disk storage system is not allowed.
If ETERNUS CLI is to be used, set "telnet" and/or "SSH" to
"Enable". If "Disable" is set, ETERNUS CLI access to the
ETERNUS DX Disk storage system is not allowed.
If monitoring software is to be used, set "Maintenance" and/or
"Maintenance-Secure" to "Enable". If "Disable" is set, monitoring
software access to the ETERNUS DX Disk storage system is not
allowed.
If the "ping" command is to be used, set "ICMP" to "Enable". If
"Disable" is set, the ETERNUS DX Disk storage system will not
be able to respond to "pings".
Check that the ETERNUS DX Disk storage system can be connected to via
each of the desired network services.
If not, contact your maintenance engineer.
Copyright 2011 FUJITSU LIMITED
"2.2 Attaching and Removing the
"2.3 Attaching and Removing the Front
82