5-16. Adjusting Trigger Hold Actuation Time

2
Tools Needed:
Nonconductive
1/4 in
OM-1594 Page 26
1
Top Of PC1
To adjust trigger hold actuation
time, proceed as follows:
1
Motor Speed Control Board
PC1
2
Potentiometer R50
.
Trigger hold actuation time
range is from 0 to 4 seconds.
To decrease trigger hold actuation
time, use a small nonconductive
screwdriver
and
rotate
potentiometer
clockwise;
increase actuation time, rotate
potentiometer counterclockwise.
Reinstall side panel.
Ref. 801 557-B / 197 716