Trigger Hold Switch; Voltage Control And Digital Meters (For Models With Meters Only) - Miller Electric SS-74D16 Swingarc Owner's Manual

Wire feeder
Table of Contents

Advertisement

5-4. Trigger Hold Switch

1
Trigger Hold Switch
Trigger hold allows the operator to weld with-
out holding the gun trigger.

5-5. Voltage Control And Digital Meters (For Models With Meters Only)

1
2
3
OM-1500−1 1 Page 18
1
To use the trigger hold function, place the
trigger hold switch in the On position.
The operator must hold the trigger for a mini-
mum of 2 seconds, but not longer than 6
seconds before releasing it. Welding will
continue when the trigger is released.
To stop welding, press the trigger again.
1
Voltmeter
Displays actual or preset voltage
from welding power source through
the 14−pin control cable.
2
Wire Speed Meter
Factory set to display inches per
minute. If display of meters per min-
ute is desired, see Section 4-13.
3
Voltage Control
Use control to adjust voltage output
of welding power source.
803 152