Adjusting Spark Gaps - Miller Electric HF-251D-1 Owner's Manual

High frequency arc starter
Table of Contents

Advertisement

5-2. Adjusting Spark Gaps

1
Tools Needed:
5/32 in
OM-611 Page 18
2
3
4
0.008 in
(0.203 mm)
Return To Table Of Contents
Turn Off unit and welding power
source and disconnect input power.
Rear Of Unit
Loosen screw on spark gap access
door and open.
1
Do not clean or dress tungsten.
Replace point if tungsten end
disappears.
2
Normal spark gap is 0.008 in (0.203
mm).
If spark gaps are okay, reinstall
door. If adjustment is needed, con-
tinue as follows:
3
Loosen screws. Place gauge of
proper thickness in spark gap.
4
Apply slight pressure at point until
gauge is held firmly in gap. Tighten
adjustment screws to 12 in/lbs
torque (overtightening will deform
plastic base). Repeat gauge adjust-
ment with other gap.
Close access door.
Tungsten End Of Point
Spark Gap
Adjustment Screws
Pressure Point
Ref. 098 956-G

Hide quick links: