7-5. Changing Gun Contact Tip

7-6. Replacing Or Cleaning Gun Drive Roll In Pistol-Grip Guns

5
3
6
2
1
4
2
7
Remove nozzle
1
Nozzle
2
FasTip
Unscrew FasTip.
Install new FasTip.
Turn Off wire feeder and welding
power source.
1
Top Cover
2
Pressure Roll Assembly
Cut off wire where it enters
pressure roll assembly area.
3
Setscrew
4
Current Pick-Up Tab
This tab helps prevent burnback
1
caused by welding arcs inside the
contact tip. This tab may be re-
moved to provide an insulated drive
roll. (If tab is removed, a smaller di-
ameter contact tip is recom-
mended. See options in Parts List.)
Lightly grease top of tab before rein-
stalling.
5
Drive Roll
Use wire brush to clean drive roll.
Install drive roll with desired groove
down, and turn drive roll so one
setscrew faces flat side of shaft.
6
Bearing
7
Liner
Line up drive roll groove with bear-
ing groove and liner opening.
Tighten setscrews.
If changing drive roll in feeder, see
Section 7-1.
Thread welding wire through gun,
and adjust drive roll pressure, if
necessary (see Section 5-13).
Close and secure pressure roll
assembly. Reinstall top cover.
Tools Needed:
5/64 in
Ref. 150 437-A
Ref. 151 599-F
OM-1594 Page 35