Initial start-up, inspection, maintenance
Further details regarding the individual steps
Adjusting heating curves (only for weather-compensated
control units)
The heating curves illustrate the rela-
tionship between the outside tem-
perature and the boiler water or the
flow temperature. To put it simply: The
lower the outside temperature, the
higher the boiler water or flow tem-
perature. The room temperature,
again, depends on the boiler water or
the flow temperature.
34
(cont.)
5. Press L and d simultaneously
for approx. 1 second. User check
completed.
Settings in the delivered condition:
&
Slope = 1.4
&
Level = 0
Generally, the slope of the heating
curve lies
in the range of A for underfloor
&
heating systems,
in the range of B for low tempera-
&
ture heating systems (according to
the Energy Savings Order [Ger-
many]).