Viessmann VITODENs 200 Installation Instructions Manual page 96

Gas fired wall mounted condensing boiler
Hide thumbs Also See for VITODENs 200:
Table of Contents

Advertisement

Troubleshooting
Checking and acknowledging faults
Fault code
Const.
in the dis-
play
dd
dE
E4
X
E5
X
E6
X
F0
X
80
Weat-
System
h.
character-
comp.
istics
X
X
X
Burner
blocked
X
Burner
blocked
X
Burner in
fault state
X
Burner
blocked
(cont.)
Cause
Room temperature
sensor heating cir-
cuit A1 lead break
Heating circuit M2
room temperature
sensor lead break
Fault - supply vol-
tage
Internal fault
Flue gas/air supply
system blocked
Internal fault
Remedy
Check the
room tem-
perature sen-
sor for
heating cir-
cuit A1
Check the
room tem-
perature sen-
sor - heating
circuit M2
Replace con-
trol unit
Check the
ionisation
electrode and
leads. Check
flue gas sys-
tem for
soundness.
Press E
Check the
flue gas/air
supply sys-
tem. Check
the air pres-
sure switch
and the inter-
connecting
cables.
Press E
Replace con-
trol unit