Clearances To Combustibles - Quadra-Fire VOYA-GRAND-MBK Installation Manual

Voyageur grand wood insert
Hide thumbs Also See for VOYA-GRAND-MBK:
Table of Contents

Advertisement

B. Clearances to Combustibles,
MANTEL
(12" max depth)
45
(1143 mm)
In Canada a full length 6 inch (152mm) S635 fl ue liner required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm) diameter fl ue liner is required as per UL 1482.
WARNING
Fire Risk.
Comply with all minimum clearances to
combustibles as specifi ed.
Failure to comply may cause house fi re.
August 3, 2015
TOP TRIM (3/4" max depth)
32 5/8
(829mm)
HEARTH EXTENSION
(MINIMUM EMBER PROTECTION)
USA 38 1/4
CANADA 46 1/4
(1175mm)
USA 17 1/2
CANADA 19 1/2
(495mm)
MANTEL DEFLECTOR
REQUIRED
HEARTH EXTENSION
(EMBER PROTECTION)
United States and Canada (UL and ULC)
22 1/2
(572mm)
NOTE: Keep Ashlip
Clear of Ashes
NOTE: Clearances may only be reduced by
means approved by the regulatory authority
having jurisdiction
7075-209E
VOYAGEUR GRAND
43
(1092 mm)
9