I. Blower Cord Installation on Left Side
The blower cord is shipped to be installed on the right side
of the appliance. You may relocate the cord so it is on the
left side.
Overview: You are removing the power cord from the blower
controls, re-routing the cord to the left side and re-installing
the power cord to the blower controls. Refer to the exploded
drawing on page 24.
1. Swing the grille down to expose the 2 bolts, one at each
end. Remove the bolts and pull blower access assem-
bly away from appliance and store away from your work
area.
2. Remove the 2 screws in the hold down bracket in front
of the blower assembly. You do not need to remove the
blower from the hold down bracket.
3. Disconnect the 2 blower wires that are attached to the
wire harness and pull the blower assembly away from the
appliance.
August 3, 2015
4. Remove the 2 screws at the top of the control plate. Push
the bottom of the control plate to the inside of the appli-
ance and partially remove the control plate assembly.
5. Locate the black and white wires that are part of the
power cord and disconnect those wires from the wire har-
ness.
6. Remove the screw that is holding the ground lug to the
control plate.
7. Use needle nose pliers to remove the strain relief that
protects the power cord from the control plate.
8. The power cord is now disconnected from the blower
control plate. Pull the cord out through the right side of
the appliance.
7075-209E
VOYAGEUR GRAND
White Wire
Black Wire
Green Grounding
Wire
Remove Screw