Clearances To Combustibles - Quadra-Fire EXPEDITION II Installation Manual

Wood insert
Hide thumbs Also See for EXPEDITION II:
Table of Contents

Advertisement

EXPEDITION II INSERT
B. Clearances to Combustibles
In Canada a full length 6 inch (152mm) S635 flue liner
required as per ULC S628.
In USA a minimum 5 ft length (1.82m), 6 inch (152mm)
diameter flue liner is required as per UL 1482.
TOP TRIM (3/4" max depth)
24-1/4 in
(616mm)
HEARTH EXTENSION
(MINIMUM EMBER PROTECTION)
USA 38-1/4
CANADA 46-1/4
(1175mm)
Figure 10.1
NOTE: If trim measurement is over 3/4 in (19mm)
in depth use mantle or side clearances
to combustibles.
MANTEL
(12" max depth)
47-3/4 in
47-3/4 in
(1213mm)
(1213mm)
40-3/4 in
40-3/4 in
(1035mm)
(1035mm)
Figure 10.2
To calculate mantel height requirement, multiply the
depth of the mantel by 0.78 inches then add 38.375
inches to the total.
10
23-3/4 in
(603mm)
34-3/4 in
(883mm)
3 in
3 in
(76mm)
(76mm)
USA 17-1/2
CANADA 19-1/2
(495mm)
HEARTH EXTENSION
(EMBER PROTECTION)
United States and Canada (UL and ULC)
Figure 10.3
Minimum Opening Dimensions Inches
A
Height
B
Front Width
C
Back Width
Depth (Steel Surround)
D
Depth (Cast Surround)
NOTE: Minimum opening dimensions include a 1/4 inch
(6mm) clearance around unit.
NOTE: Keep Ashlip
Clear of Ashes
Figure 10.4
NOTE: Clearances may only be reduced by means
approved by the regulatory authority
having jurisdiction
Fire Risk.
Comply with all minimum clearances to
combustibles as specified.
Failure to comply may cause house fire.
7095-802B
A
D
C
B
23-3/8
32
23-7/8
18-1/4
17-1/2
WARNING
Millimeters
594
813
606
464
445
July 30, 2019