DRIVING A FASTENER
See Figure 9.
WARNING:
Never wedge or hold back the workpiece contact
mechanism during operation of the tool. Doing so could
result in possible serious injury.
SINGLE SEQUENTIAL ACTUATION
Single sequential actuation provides accurate fastener
placement.
 Connect the tool to the air supply.
 Grip the tool firmly to maintain control. Position the nose
of the tool onto the work surface.
 Push the tool against the work surface to depress the
workpiece contact.
 Pull the trigger to drive a fastener.
 Allow the tool to recoil away from the work surface as the
fastener is driven.
WARNING:
During normal use the tool will recoil immediately
after driving a fastener. This is a normal function of
the tool. Do not attempt to prevent the recoil by holding
the nailer against the work. Restriction to the recoil can
result in a second fastener being driven from the nailer.
Grip the handle firmly, let the tool do the work, and do
not place second hand on top of tool or near exhaust at
any time. Failure to heed this warning can result in serious
personal injury.
OPERATION
SETTING THE AIR PRESSURE
The amount of air pressure required will depend on the size
of the nail and the workpiece material.
Begin testing the depth of drive by driving a test nail into the
same type of workpiece material used for the actual job.
Drive a test nail with the air pressure set at 90-95 psi. Raise
or lower the air pressure to find the lowest setting that will
perform the job with consistent results.
It may be possible to achieve the desired depth with air
pressure adjustments alone. If finer adjustments are needed,
use the drive depth adjustment on the tool.
14
TRIggER
woRKPIECE ConTaCT
Fig. 9