I Connections of Matrix Switchers (WJ-SX650 Series) and a PS·Data
System Controller
By connecting a PS·Data system controller (WV-CU950/650, CONTROLLER NO.: 1) to the DATA ports of the units with Cable
Kit WV-CA48/10K, you can control these units from the system controller. (Refer to p. 36 for details on connections.)
Notes:
• Connect Cable Kit WV-CA48/10K to the DATA 1 port.
• Set the DATA 1 port of each unit to PSD. Setting changes are performed in "System" – "DATA Port" of WJ-SX650 Series
Administrator Console or DATA PORT (refer to p. 53) of SETUP MENU.
Unit Address: 1
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
Connections and Operations
• When controlling two or more units from a PS·Data system controller, you need to select a unit before operation. To select a
unit, enter a unit address by pressing the numeric buttons. Then, press the RECORDER/UNIT button while holding down
the SHIFT button.
• The unit address setting of each unit must be different from each other. The unit address settings are performed in
"Communication" – "PS.Data" of WJ-SX650 Series Administrator Console.
• When an alarm occurs to a unit, other units will accept the alarm as a serial alarm input.
• User level settings for alarm suspension must be the same within all the units.
• The LCN settings must be different among all the units. (Up to LCN 999 are available.) The LCN settings are performed in
"System" – "Logical Camera Number" of WJ-SX650 Series Administrator Console.
• When activating AUTO RESET, set the parameter to 3 sec or longer. (Refer to p.50.)

I Controlling from a Web Browser Accessing a Recorder

If a recorder is connected to the unit, you can control cameras using a web browser of a PC accessing the recorder. You can
set priority for web browser control. Priority setting is performed in "Operator" – "Operator" of WJ-SX650 Series Administrator
Console.
Notes:
• Refer to the operating instructions of recorder for details on browser control.
• When using WJ-RT416 Series, use the monitoring software.
Refer to the operating instructions of the monitoring software for further information about operations.
• Regardless of priority setting, during the recorder control from a system controller, camera control is not available from a
web browser accessing recorders connected to the same DATA port in the daisy chain.

I Controlling from a PC

You can perform the operations and functions of system controllers by logging into the system and sending RS-232C com-
mands from a PC connected to the unit. Refer to Serial (RS-232C) Connector Command Reference (PDF file on the supplied
CD-ROM) for available commands.
Unit Address: 2
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
650
650
Matrix Switcher WJ-SX
CONTROLLER NO.: 1
OPERATE
OPERATE LED WILL BLINK
IF COOLING FAN MALFUNCTIONS
650
650
Matrix Switcher WJ-SX
Cable Kit
WV-CA48/10K
A
B
SYSTEM CONTROLLER
Unit Address: 3
650
650
Matrix Switcher WJ-SX
87

Advertisement

Table of Contents
loading

Table of Contents