Alarm Descriptions

I Alarm Occurrence

When this unit accept an alarm input signal (terminal alarm, camera alarm, recorder alarm, serial alarm, or video loss), an
alarm event (tour sequence, etc.) is activated automatically. Each alarm input signal is associated with an alarm event setting.
(The setting activates the alarm input signal and alarm event.) Up to 1 024 alarm event settings are available. The alarm event
setting is performed in "Alarm" – "Alarm Event" of WJ-SX650 Series Administrator Console.
By performing the settings of "Alarm Event", the following events will be activated when this unit accepts an alarm input signal.
• Alarm event information will be displayed on the associated monitors (Refer to p. 13 Monitor Display Information.)
• Depending on the setting of "Display Mode", camera images will be displayed, or sequences will be activated on the asso-
ciated monitors. In this document, these actions are mentioned as the alarm mode, and pictures displayed during the
alarm mode is mentioned as alarm pictures.
• Depending on the setting of "Recording Source (LCN)", event recording will be activated. (Recording will follow the com-
mand alarm setting and event recording setting of recorder. Refer to the operating instructions of recorder for details.)
• Depending on the setting of "Alarm Output", alarm output signal will be supplied from the video output board, and external
alarm devices (buzzer, etc.) can be activated.
Notes:
• To activate alarm output signals from the ALARM OUT 1/2 port, perform settings of No.1 to 64. No.65 and greater are
assigned for serial commands.
• To activate alarm output signals as a serial command, serial command settings are required. The settings are per-
formed in "Communication" – "Serial Command" of WJ-SX650 Series Administrator Console.
• ALARM indicators of all system controllers blink.
• Up to 10 000 alarm records are saved chronologically. The latest 1 000 alarm records can be displayed as the alarm his-
tory on the monitor. (Refer to p. 70 Alarm History Display.) The Alarm History can be downloaded from the PC to the unit.
• Alarm information is notified to the PC in serial commands. The serial command setting is performed in "Communication" –
"Serial Command" of WJ-SX650 Series Administrator Console.
Camera 100
N o. 11 (D is h)
Terminal alarm setting
No.
Display Mode
256
SPOT
Preset Position 1
(Zooming in No.1 (Entrance))
Terminal Alarm
256
No.1 (Entrance)
N o. 10 (P ot )
Infrared sensor
Spot
LCN
100
This unit
Alarm Output 50
650
650
Matrix Switcher WJ-SX
Monitor 5
Notifies the
Alarm input signal
from a sensor
alarm event
occurrence.
Alarm Input 256
Sensor
system
Monitor
Preset
1
5
Records the image
of Camera 100.
(Recording follows
the command alarm
setting and event
recording setting of
recorder.)
MONITOR1
STOP
PLAY
PAUSE
REC - REC STOP
PULL
MONITOR2
TIMER
1
2
3
4
REV
FWD
ERROR
PAN/
GOTO
ALARM
TILT
LAST
SEARCH
SHIFT
SEQ
OSD
SETUP
5
6
7
8
ZOOM/
A-B
SLOW
PAN/TILT
/ESC
ALARM
FOCUS
REPEAT
+
SUSPEND
ALARM
RESET
DISK SELECT
COPY
TEXT
MARK
9
10/0
11
12
IRIS
LISTED
HDD 1
PRESET
OPERATE
EL-ZOOM
LOGOUT
/AUTO
HDD 2
13
14
15
16
SET
Digital Disk Recorder
BUSY
WJ-HD
Recorder 1
PC
Recording
Alarm Output
Source (LCN)
100
50
67

Advertisement

Table of Contents
loading

Table of Contents