Exiting A Location; Exiting The Program Mode; Programming Data Types; Numerical Data - GE NetworX NX-6V2 Installation And Startup

Hide thumbs Also See for NetworX NX-6V2:
Table of Contents

Advertisement

the [MEDICAL] key. To review the data in a location, repeat the above procedure, pressing [r] without any numeric data entry. Each time
[r] is pressed, the programming data of the next segment will be displayed for review.

EXITING A LOCATION

After the last segment of a location is programmed, pressing [r] will exit that location, turn the "Ready" LED off and the "Armed" LED on.
The [r] must be pressed or the data will not be saved. To exit before the last segment, press [#]. As before, you are now ready to enter
another programming location. If an attempt is made to program an invalid entry for a particular segment, the keypad sounder will emit a
triple error beep (beep, beep, beep), and remain in that segment awaiting a valid entry.

EXITING THE PROGRAM MODE

When all the desired changes in programming have been made, it is time to exit the program mode. Pressing [Exit] will exit this
programming level, and go to the "Select a Module To Program" level. If no additional modules are to be programmed, pressing [Exit]
again will exit the program mode. If there is a module to be programmed, it may be selected by entering its address followed by [#] (see
"Selecting the Module To Program" above). The procedure for programming these devices is the same as for the control panel, except the
locations will be for the module selected.
VIII.

PROGRAMMING DATA TYPES

Programming data is always one of two types. One type of data is numerical and can take on values from 0 to 15 or 0 to 255 depending on
the location's segment. The other type of data is a feature selection type. Feature selection data is used to turn features on or off.
Examples are shown on page 10. Use the following procedures when working with these two data types.

NUMERICAL DATA

Numerical data is programmed by entering a number from 0-255 on the numeric keys of the system keypad. To view the data in a
location, a binary process is used. With this process, the LEDs for zones 1 through 8 are utilized, and the numeric equivalents of their
illuminated LEDs are added together to determine the data in a programming location. The numeric equivalents of these LEDs are as
follows:
Zone 1 LED = 1
Zone 5 LED = 16
Example: If the numerical data to be programmed in a location is "66", press [6]-[6] on the keypad. The LEDs for Zone 2 and Zone 7 will
become illuminated indicating 66 is in that location (2 + 64 = 66). See this example on page 10. Once the data is programmed, press [r] to
enter the data and advance to the next segment of that location. After the last segment of a location is programmed, press [r] to exit that
location, turn the "Ready" LED off and the "Armed" LED on. As before, you are now ready to enter another programming location. If an
attempt is made to program a number too large for a particular segment, the keypad sounder will emit a triple beep, indicating an error, and
remain in that segment awaiting a valid entry. On the LCD keypad, the number in the location will be displayed. For locations with a
maximum of 15, the hexadecimal equivalent will be displayed in parenthesis. Example: 11 (B) or 14 (E).

FEATURE SELECTION DATA

Feature selection data will display the current condition (on or off) of eight features associated with the programming location and segment
selected. Pressing a button on the touchpad (1 thru 8) that corresponds to the "feature number" within a segment will toggle (on/off) that
feature. Pressing any numeric key between [1] and [8] for selection of a feature, will make the corresponding LED illuminate (feature ON).
Press the number again, and the LED will extinguish (feature OFF). You will see that numerous features can be selected from within one
segment. For instance, if all eight features of a segment are desired, pressing [1]-[2]-[3]-[4]-[5]-[6]-[7]-[8] will turn on LED's 1 thru 8 as you
press the keys, indicating that those features are enabled. LCD Keypad Note: The numbers of the enabled features will be displayed.
However, the features not enabled will display a hyphen (-). After the desired setting of features is selected for this segment, press [r].
This will enter the data and automatically advance to the next segment of the location. When you are in the last segment of a location and
press [r] to enter the data, you will exit that location. This will now turn the "Ready" LED off and the "Armed" LED on. As before, you are
now ready to enter another programming location.
NX-6V2 Control
Zone 2 LED = 2
Zone 6 LED = 32
Zone 3 LED = 4
Zone 7 LED = 64
Zone 4 LED = 8
Zone 8 LED = 128
9